How long will a 6 kW hybrid inverter with a 5 kWh lithium battery last?

From a full battery it runs 3 ceiling fans, 6 LED bulbs and a Wi-Fi router for about 11 h. During daily load-shedding of 6 h (city pattern), a typical home gets 7.8 h per cut.

Backup by what you run

A 6 kW hybrid inverter (48 V) gives about 6000 W at once. The battery bank holds 4,800 Wh.

Backup from a full battery, everything on at once
What runsUsesBackup
2 ceiling fans and 4 LED bulbs208 W16 h
3 ceiling fans, 6 LED bulbs and a Wi-Fi router324 W11 h
A fridge, 2 ceiling fans and 4 LED bulbs283 W12 h
4 ceiling fans, 8 LED bulbs, a router and a 32-inch TV478 W7.4 h
6 ceiling fans, 10 LED bulbs, a router and a TV662 W5.4 h
A 1-ton inverter AC and 2 ceiling fans860 W4.2 h
A 1.5-ton inverter AC, 4 ceiling fans and 8 LED bulbs1416 W2.6 h

"Too much" means the UPS would trip: it gives about 6000 W at once. A fridge's motor runs about half the time, so it uses less than its rating on average. Figures are for a healthy battery; an old or hot one gives less.

How many fans can it run?

Up to about 75 ceiling fans of 80 W at once, if nothing else is on. More fans means less time:

Ceiling fans only, from a full battery
FansBackup
1 fan38 h
2 fans21 h
3 fans14 h
4 fans11 h
6 fans7.4 h
8 fans5.6 h
10 fans4.5 h
12 fans3.8 h

Real backup during load-shedding

For a typical home: 3 ceiling fans, 4 LED bulbs, a Wi-Fi router, 2 phones charging, a fridge and a 32-inch TV in the evening.

A typical home, once the battery has settled
CutsPatternStays onPer cut
Light4 h a day4 h of 4 h7.8 h
City6 h a day, 1 h every 4 h6 h of 6 h7.8 h
Heavy10 h a day, 2 h cuts10 h of 10 h7.8 h
Rural16 h a day, 4 h off and 2 h on16 h of 16 h7.8 h

With city load-shedding everything stays on through every cut: the charger refills the battery between cuts. Longer daily cuts are where it starts to fall short.

Open this setup in the planner

The planner opens with this UPS and battery and a typical home's appliances; change anything to see your own backup.

Other setups

Figures are from LoadReserve's calculation with typical values; see how it works.